5.3 Fuse Replacement
The fuse is accessible on the rear panel power module
of the UIO-256. Remove the power cord from the
power module and free the fuse cartridge as shown
Figure 7. Be sure to replace the fuse with a fuse of the
same rating and type.
110
220
USE ONL
YWITH A 250V FUSE
6. Specifications
Power
110/220 VAC, 50/60 Hz (selectable via backpanel)
Dimensions
1RU High x 7” (178mm) deep behind front panel
GPI Inputs
Type: Optically coupled
Input Requirements: 5-18 VDC
GPI Outputs
Type: DPDT Relays with common, normal-open
and normal -closed contacts
Contact Ratings: 0.5A at 120 VAC; 1A at 24 VDC;
0.3A at 60 VDC
Figure 7. Fuse Replacement
Przeglądanie stron 9