7 Installation Notes
7.1 General Installation Procedure
These are the steps that you should generally use to get
your Zeus intercom system up and running.
1. Unpack and inspect the equipment.
2. Organize a set of equipment manuals. (You may have
several copies of some types, keypanel manuals, for
example.)
3. Mount the Zeus frame and connect it to the
configuration computer.
4. Install ZEUSedit on the configuration computer.
5. Log on to Zeus from ZEUSedit.
You may wish to run the 1studio.zus example and
take a few minutes to familiarize yourself with the
software (recommended).
6. Begin connecting keypanels and other components.
Verify operation of components as they are
connected.
7. Configure the intercom system using ZEUSedit.
Perform periodic downloads to check progress.
8. When you finish naming things, you can print out the
name lists and distribute them if desired. KP95-0
Keypanels: When you finish assigning keys, you can
print out designation strips, cut them to size, and
insert them into the holders on the KP95-0 keypanels.
9. Perform any input and/or output gain adjustments for
any audio devices that are operating at non-standard
levels. (Use this adjustment when the level for a
particular device needs to be adjusted throughout the
intercom system.)
10. Adjust any crosspoint and party line gains as needed.
(Use these adjustments when you want to adjust the
mix for individual users.)
11. Set up dim tables as required if there are any
feedback problems between intercom stations
operating in close proximity to one-another.
12. This completes the general installation procedure.
You may also wish to make use of the Logging and
Partial Save features of ZEUSedit. Logging is
available on the Logging menu. Logging basically
keeps track of key activations, which can sometimes
be useful for diagnostic purposes. Partial Save is
available on the File menu. Partial Save lets you set
up configuration files to make routine changes to
portions of your intercom system setup.
7.2 Unpacking the Equipment
As soon as possible after receipt, inspect the container(s)
and contents for physical damage that may have occurred
in shipping. If damage has occurred, immediately (within
24 hours of receipt of equipment) contact the carrier in-
volved and file a claim. Save all packing materials, and
request an immediate inspection by the carrier’s insurance
claims agent. Refer to the equipment manuals for each
item for any information about items packed with that
equipment.
For information about returns to RTS, refer to the
front of this manual.
7.3 Zeus Mounting Precautions
Important! Leave at least 1 rack unit of space
above and below Zeus and do not obstruct the
cooling vents at the sides. Also, do not mount Zeus
near any other component that generates an unusual
amount of heat.
7.4 AC Power Connection
1. Place the AC switch on the back panel in the off (O)
position.
2. Connect the AC power cord.
7.5 Computer Connection
1. Turn the computer off.
2. Connect the computer cable to J25 on the back of
Zeus.
3. Connect the other end of the cable to any available
COM port on the computer. The COM ports may be
labeled COM 1, COM 2 etc. and may also be
identified by any of the following symbols.
If you need a longer computer cable, you can
construct one using Figure 15, page 23.
Getting Started, Zeus™ DSP Intercom Matrix 25
COM port symbols
Przeglądanie stron 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 36 37

Komentarze do niniejszej Instrukcji

Brak uwag