RTS WM300 Instrukcja Użytkownika Strona 4

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 13
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 3
SECTION I:
DESCRIPTION AND SPEClFICA TIONS
1.2 MODEL PSIS SPECIFICATIONS
1.1 DESCRIJYrION
Outputs
One powered channel, CHI, (audio + DC + 200
ohm/400 ohm 10% termination}, and one passive chan-
nel' CH2, (audio + 200/400 ohm 20% termination}.
The Model PS 15 Power Supply is designed to work within
the TW Intercom System. The PS 15 is suitable for small to
medium sized TW Intercom Systems.
Output Voltage
No Load
Full Load
32.0 +2.0. -1.0 volts
24.0 volts. nominal
The unit is self-contained and features two-channel opern-
tion: one "wet" channel with 24 to 32 volts DC and one
"dry" channel without voltage potential. Each channel
provides an audio termination impedance of 200 or 400
ohms (switch selectable).
Output Impedance
200 or 400 ohms 20%. switchable. On powered
channel. 200 ohms. nominal. is maintained from 18.0
to 33.0 volts.
This power supply allows speech signals and DC to exist on
the same wire (Channel I). The power supply's outputs are
protected against short circuit conditions with recovery
being automatic and instantaneous.
Output Current
S13nd'Jfd Option
*p Option (234 V)
#D Option (IOOV)
Fault Current
.9 ampere at 21/+4-2 volts. DC
.9 ampere at 21/+4-2 volts. DC
.8 ampere at 21/+4-2 volts. DC
1.5 amperes at 0.0 volts. DC
A single PS 15 Power Supply can power 6 to 30 user stations
(depending on model and combination -see specifications).
Signal Level
Nominal
Maximum
If still more user stations are needed, two PS 15 Power
Supplies can be coupled together to double the powering
capability: a 1/4-inch 3-circuit phone jack is available on
each power supply for this purpose. This connector can also
be used as a one-way output port when monitoring or
recording the intercom audio signals.
2.0 volts peak to peak
5.0 volts peak to peak
Frequency Response
100 hertz to 20 kilohertz +1, -5 dB
When two PS15 supplies are combined. toggling a rear
pmlel switch on each supply will keep the audio level
constallt. Two PS 15. s can power as many stations as a PS31
(with DC load evenly distributed between the two supplies).
Since the PS31 supplies more voltage than the PS15 under
full load. the PS31 is better suited to power a large system
spread over a large area.
Signal-to-Noise Ratio
Reference 2.0 volts. peak to peak: 60 dB nomina]
Mains Voltage
Standard
*POption
#D Option
117 volts :t10%. 50 -60 hertz
234 volts :t10% 50-60 hertz
100 volts +10%. -5%.50-60 hertz
There are two XLR-type 3-pin male connectors mounted on
the rear panel for output interconnection to the user stations.
Mains Amperes
0.40 at 117 volts :t10%, 50-60 hertz
0.20 at 234 volts :t10%, 50-60 hertz
0.40 at 100 volts +10%, -5%,50-60 hertz
The PS 15 has been designed to meet UL 1419 specifications
(professional Audio and Video Equipment).
Environmental
Temperature
Operating
StoralJe
o
Humidity
The PSIS Power Supply may be used in portable applica-
tions (use optional MCP8 channels) or in standard EIA
equipment racks (use optional MCPl or MCP2 rack mount-
ing kits).
00 to 50°C
-40° to 70°C
0 to 95(.70, non-condensing
Dimensions
Height
Width
Depth
The PS 15 is one rack unit high and one-half rack wide. A
single PS 15 may be rack -mounted singly or two PS 15. s may
be mounted side-by-side.
1.72 inches (44 millimeters)
8.186 inches (207.9 millimeters)
8.33 inches (211.6 millimeters)
Weight
PSl5
MCPl
MCP2
4.29 pounds (1.95 kilograms)
1.0 pounds (0.454 kilograms)
1.0 pounds (0.454 kilograms)
Finish
Thennoplastic front panel. aluminum case. light gray
finish