11
Each LCP-32 adjusts the listen levels for 16 keypanel keys, and you can connect as many LCP-32 panels as
required to adjust all keys on the KP-32 and on an optional EKP-32 Expansion Panel. An interconnect
cable is supplied with each LCP-32. Connect the first LCP-32 to the LCP connector on the KP-32. Connect
the second LCP-32 to the first LCP-32, and so forth. Note, when arranging LCP-32 panels in an equipment
rack, you should put them directly above or below the keys they will be used to adjust. See also, “Service
Menu, LCP-32”, page 40.
Frame Connector
Use either of the
Frame
connectors (but not both) to connect to an intercom port of the intercom system.
The intercom port you connect to should agree with the address that you set previously. Cable wiring
diagrams are shown in Figure 1 and Figure 2.
DE-9P (MALE)
TO KEYPANEL
DE-9S (FEMALE)
TO INTERCOM SYSTEM*
CABLE TYPE:
BELDEN 8777
1
2
6
4
5
9
7
8
3
1
2
6
4
5
9
7
8
3
DATA
AUDIO TO MATRIX
AUDIO FROM MATRIX
+
-
+
-
-
+
When connecting to an ADAM CS back panel, use
only low-profile cable connectors such as AMP
Part No. 747516-3 (Telex Part No. 59926-678)
IMPORTANT!
*
Figure 1. DE9S Intercom Cable Wiring
3 TWISTED PAIR TELEPHONE CABLE
1
2
3
4
5
6
DATA -
1
2
3
4
5
6
AUDIO FROM MATRIX +
AUDIO TO MATRIX -
DATA +
123456
CONTACTS
LATCH
RJ12 MODULAR PLUG
AMP 5-555042-3 or equivalent
(View from cable entrance)
Use AMP Chordal
Crimp Tool 231648-1
or equivalent
PAIR 1: AUDIO TO MATRIX
PAIR 2: AUDIO FROM MATRIX
PAIR 3: DATA
AUDIO FROM MATRIX -
AUDIO TO MATRIX +
Figure 2. RJ12 Intercom Cable Wiring
Komentarze do niniejszej Instrukcji